CCMC 13500-R

Evaluation · Fiberon Composites LLC

CCMC 13500-R

Evaluation

Fiberon Composites LLC

Products
  • Concordia Astir Collection
  • Fiberon®Horizon Decking
  • Fiberon®Sancutary Decking
  • Fiberon®Symmetry™ Decking
  • Good Life Escapes Collection
  • Good Life Weekender Collection
Criteria
CCMC-TG-067314.01-10
MasterFormat
06 73 00, 06 73 13
Categories
Deck boards and railings
Status
In the registry
Tracked since
November 9, 2026

The NRC report is the authoritative copy, with the conditions and limitations of use.

Same criteria (10)

Records assessed to CCMC-TG-067314.01, any edition.

  • CCMC 13125-R Trex Company, Inc. · Trex® Enhance® decking and 3 more
  • CCMC 13191-R Deckorators, Inc. · MoistureShield®Vantage Decking and 1 more
  • CCMC 13378-R Universal Consumer Products · DecKorators®Composite Deck Board and 1 more
  • CCMC 13569-R Avon Plastics, Inc. · Armadillo Heritage Composite Decking and 1 more
  • CCMC 14086-R NEWTECHWOOD CORPORATION · NewTechWood UltraShield®
  • CCMC 14089-R Asahikoushin (Shanghai) CO. Ltd. · Asahikoushin WPC Decking
  • CCMC 14114-R Universal Consumer Products · Veranda Wood/Plastic Composite Deck Board
  • CCMC 14154-R UFP Ventures II, Inc. · Tropics Deckboard
  • CCMC 15042-R Trunorth Composites Inc. · Accuspan Square Edge and Grooved Edge decks boards

History

  • November 9, 2026 First seen in the registry

BCINs.ca has tracked the registry daily since November 9, 2026. "First seen" is when we first saw the record, not when CCMC issued it; the NRC report has the dates.

Using a CCMC-assessed product in Ontario. Since July 1, 2025, a product with a CCMC evaluation no longer needs a Minister's Ruling before it can be used in Ontario.¹ A CCMC assessment does not on its own mean a product meets the Building Code. An evaluation (numbers ending in R) is evidence you can give the chief building official or registered code agency to support using the product as an alternative solution.² A listing (ending in L) shows the product conforms to a standard named in the listing. Either way, the product has to be used within the conditions and limitations in the NRC report, and the building official decides whether it is acceptable for your project.

  1. ¹ Building Code Act, 1992, S.O. 1992, c. 23, clause 29(1)(a), repealed by the Protect Ontario by Building Faster and Smarter Act, 2025, S.O. 2025, c. 9, Sched. 1, s. 2(1), in force July 1, 2025.
  2. ² O. Reg. 163/24 (2024 Building Code), Division A, Sentence 1.2.1.1.(1), and Division C, Article 2.1.1.1.

Data from the NRC CCMC Registry of Product Assessments API, last synced November 10, 2026, 2:19 a.m. ET. Always confirm current status and the conditions and limitations in the NRC report before use. BCINs.ca is not affiliated with NRC or CCMC.